Experiencing Bluetooth® issues with Go Direct® sensors on Chromebooks? Get help here.

Go Direct® Drop Counter

Go Direct® Drop Counter

Go Direct® Drop Counter

$109.00

The Go Direct Drop Counter precisely records the number of drops of titrant added during a titration and then automatically converts it to volume. It connects via Bluetooth® wireless technology or via USB to your device.

ORDER CODE: GDX-DC Categories ,

Conducting a titration has never been easier. Use Go Direct Drop Counter in conjunction with our other Go Direct sensors, such as Go Direct pH, Go Direct Conductivity, or Go Direct ORP, to perform acid-base, conductometric, or potentiometric titrations.

Designed with a wide drop-detecting area, Go Direct Drop Counter removes the need for precise burette alignment. We’ve also included a large sensor slot for conventional stick-style sensors and a smaller, adjustable slot for temperature probes. The adjustable clamp easily fits our Stir Station and most laboratory ring stands and lattices.

Rechargeable Battery—Ready When You Are

The robust rechargeable battery offers long battery life and provides always-ready operation when using the sensor wirelessly. Monitor battery life directly from our award-winning Vernier Graphical Analysis® app, as well as LabQuest® 3. Should the battery run low, simply connect the sensor to the charging cable and keep on collecting—no interruptions or inconvenience to you or your students.

Wireless or Wired—The Flexibility to Choose

Our Go Direct sensors connect directly to your mobile device, Chromebook™, or computer using our Vernier Graphical Analysis® app—no additional equipment or software purchases are necessary. Go Direct sensors can be used wired via USB or wirelessly via Bluetooth® wireless technology, allowing you to choose the best solution for your classroom or laboratory.

Strong Acid and Base Titration Using Go Directâ„¢ pH
Strong Acid and Base Titration Using Go Direct® pH (5:46)

Specifications

  • Accurate drop counting at rates up to 6 drops/s
  • Dimensions:
    • Opening for drops: 3 cm
    • Openings for sensors (diameter): 7 mm and 13 mm
    • Ring stand opening: 16 mm
    • Total length: 15.5 cm, width: 4.5 cm, height: 1.8 cm
    • Distance from center of ring stand opening to center of drop opening (ideal): 10.5 cm
    • Distance from center of ring stand opening to center of sensor opening (ideal): 12 cm
  • Connections:
    • Wireless: Bluetooth
    • Wired: USB

Experiments

High School (16 experiments)
College (8 experiments)

Requirements

Choose a platform below to see its compatibility requirements.

LabQuest
InterfaceLabQuest App
LabQuest 3Full support
LabQuest 2 (discontinued)Full support 1
LabQuest (discontinued)Incompatible

Compatibility Notes

  1. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.
Computers
Software
InterfaceGraphical Analysis
No interface requiredFull support 1 2
LabQuest 3Full support 3
LabQuest 2 (discontinued)Full support 3 4

Compatibility Notes

  1. For Bluetooth® connectivity, only computers running Windows 10 or Mac OS X 10.10 or newer are supported. The computer must also have a compatible Bluetooth 4.0+ radio.
  2. Use with an electrode such as a pH Sensor, Conductivity Probe, or ORP Sensor.
  3. Connect this sensor directly to a computer or Chromebook via a USB or wireless Bluetooth® connection for best results. Alternatively, this sensor is fully supported when used with LabQuest 2 or LabQuest 3 when the LabQuest is connected to a computer or Chromebook via Wireless Data Sharing.
  4. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.
Chromebook
Software
InterfaceGraphical Analysis
No interface requiredFull support 1
LabQuest 3Full support 2
LabQuest 2 (discontinued)Full support 2 3

Compatibility Notes

  1. Use with an electrode such as a pH Sensor, Conductivity Probe, or ORP Sensor.
  2. Connect this sensor directly to a computer or Chromebook via a USB or wireless Bluetooth® connection for best results. Alternatively, this sensor is fully supported when used with LabQuest 2 or LabQuest 3 when the LabQuest is connected to a computer or Chromebook via Wireless Data Sharing.
  3. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.
iOS
Software
InterfaceGraphical AnalysisGraphical Analysis GW
No interface requiredFull support 1Full support 1
LabQuest 3Full support 2 3Full support 2 3
LabQuest 2 (discontinued)Full support 2 3 4Full support 2 3 4

Compatibility Notes

  1. Use with an electrode such as a pH Sensor, Conductivity Probe, or ORP Sensor.
  2. Connect this sensor directly to a supported mobile device via a wireless Bluetooth® connection for best results.
  3. iOS and Androidâ„¢ devices can only connect to LabQuest 2 or LabQuest 3 via Wireless Data Sharing.
  4. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.
Android
Software
InterfaceGraphical AnalysisGraphical Analysis GW
No interface requiredFull support 1Incompatible 1
LabQuest 3Full support 2 3Full support 2
LabQuest 2 (discontinued)Full support 2 3 4Full support 2 4

Compatibility Notes

  1. Use with an electrode such as a pH Sensor, Conductivity Probe, or ORP Sensor.
  2. iOS and Androidâ„¢ devices can only connect to LabQuest 2 or LabQuest 3 via Wireless Data Sharing.
  3. Connect this sensor directly to a supported mobile device via a wireless Bluetooth® connection for best results.
  4. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.
Python
Software
InterfacePython
No interface requiredFull support
Javascript
Software
InterfaceJavascript
No interface requiredFull support 1

Compatibility Notes

  1. A wireless Bluetooth® connection can be made with Go Direct sensors on any platform running a browser with WebBluetooth support. However, only a few operating systems have been tested and testing has been limited.
LabVIEW
Software
InterfaceNI LabVIEW
No interface requiredFull support 1

Compatibility Notes

  1. For Bluetooth® connectivity, only computers running Windows 10 or Mac OS X 10.10 or newer are supported. The computer must also have a compatible Bluetooth 4.0+ radio.

What's Included

  • Go Direct Drop Counter
  • Plastic reagent reservoir
  • Plastic valve with a double stopcock fitting
  • Vernier Microstirrer
  • Micro USB Cable

Accessories

AccessoryOrder CodePriceQuantity
Go Direct® Charge StationGDX-CRG$89.00
Replacement PartOrder CodePriceQuantity
Micro USB to USB-C CableCB-USB-C-MICRO$9.00
Plastic 2-Way ValvePS-2WAY$2.00
Stopper StemPS-STEM$1.00
MicrostirrerMSTIR$9.00
Reagent Reservoir, 2 Valves, and TipVDC-RR$10.00
Micro USB CableCB-USB-MICRO$5.00
Go Direct® 300 mAh Replacement BatteryGDX-BAT-300$10.00

Support

Educational use only: Vernier products are designed for educational use. They are not appropriate for industrial, medical, or commercial applications.

SAVE/SHARE YOUR CART