Go Direct® CO2 Gas Sensor

Go Direct® CO2 Gas Sensor

Go Direct® CO2 Gas Sensor

$225.00

The Go Direct CO2 Gas Sensor measures gaseous carbon dioxide concentration levels, air temperature, and relative humidity. It can be used in a variety of biology experiments. It connects via Bluetooth® wireless technology or via USB to your device.

ORDER CODE: GDX-CO2 Categories ,

Monitor changes in carbon dioxide, temperature, and relative humidity easily with the Go Direct CO2 Gas Sensor. This sensor includes built-in temperature compensation and humidity protection. A 250 mL Nalgene bottle is included for running controlled experiments with small plants and animals.

The Go Direct CO2 Gas Sensor is ideal for the following experiments:

  • Measure the change in gas concentration during cellular respiration.
  • Measure the change in gas concentration during photosynthesis.
  • Study the effect of temperature on cell respiration or metabolism of organisms.
  • Investigate artificial selection in yeast by comparing respiration rates of different strains.

Rechargeable Battery—Ready When You Are

The robust rechargeable battery offers long battery life and provides always-ready operation when using the sensor wirelessly. Monitor battery life directly from our award-winning Vernier Graphical Analysis® app, as well as LabQuest® 3. Should the battery run low, simply connect the sensor to the charging cable and keep on collecting—no interruptions or inconvenience to you or your students.

Wireless or Wired—The Flexibility to Choose

Our Go Direct sensors connect directly to your mobile device, Chromebook™, or computer using our Vernier Graphical Analysis® app—no additional equipment or software purchases are necessary. Go Direct sensors can be used wired via USB or wirelessly via Bluetooth® wireless technology, allowing you to choose the best solution for your classroom or laboratory.

Monitor Cell Respiration Using Go Direct® CO₂ Gas
Monitor Cell Respiration Using Go Direct® CO2 Gas (4:43)

Specifications

  • CO2 Sensor
    • Type: NDIR
    • Range: 0–100,000 ppm
    • Accuracy
      • 0 to 1,000 ppm: ±100 ppm
      • 1,000 to 10,000 ppm: ±5% of reading + 100 ppm
      • 10,000 ppm to 50,000 ppm: ±10% of reading
      • 50,000 to 100,000 ppm: ±15% of reading
    • Resolution: 1 ppm CO2
  • Temperature Sensor
    • Type: integrated circuit (IC)
    • Accuracy: ±0.5°C
    • Resolution: 0.1°C
  • Relative Humidity Sensor
    • Type: integrated circuit (IC)
    • Accuracy: ±5% or better
    • Resolution: 0.1%
  • Dimensions
    • Sensor shaft length: 82 mm
    • Sensor shaft diameter: 28 mm
    • Total length: 200 mm
  • Connections
    • Wireless: Bluetooth
    • Wired: USB

Experiments

High School (23 experiments)
College (23 experiments)

Requirements

Choose a platform below to see its compatibility requirements.

LabQuest
InterfaceLabQuest App
LabQuest 3Full support
LabQuest 2 (discontinued)Full support 1
LabQuest (discontinued)Incompatible

Compatibility Notes

  1. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.
Computers
Software
InterfaceGraphical Analysis
No interface requiredFull support 1
LabQuest 3Full support 2
LabQuest 2 (discontinued)Full support 2 3

Compatibility Notes

  1. For Bluetooth® connectivity, only computers running Windows 10 or Mac OS X 10.10 or newer are supported. The computer must also have a compatible Bluetooth 4.0+ radio.
  2. Connect this sensor directly to a computer or Chromebook via a USB or wireless Bluetooth® connection for best results. Alternatively, this sensor is fully supported when used with LabQuest 2 or LabQuest 3 when the LabQuest is connected to a computer or Chromebook via Wireless Data Sharing.
  3. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.
Chromebook
Software
InterfaceGraphical Analysis
No interface requiredFull support
LabQuest 3Full support 1
LabQuest 2 (discontinued)Full support 1 2

Compatibility Notes

  1. Connect this sensor directly to a computer or Chromebook via a USB or wireless Bluetooth® connection for best results. Alternatively, this sensor is fully supported when used with LabQuest 2 or LabQuest 3 when the LabQuest is connected to a computer or Chromebook via Wireless Data Sharing.
  2. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.
iOS
Software
InterfaceGraphical AnalysisGraphical Analysis GW
No interface requiredFull supportFull support
LabQuest 3Full support 1 2Full support 1 2
LabQuest 2 (discontinued)Full support 1 2 3Full support 1 2 3

Compatibility Notes

  1. Connect this sensor directly to a supported mobile device via a wireless Bluetooth® connection for best results.
  2. iOS and Androidâ„¢ devices can only connect to LabQuest 2 or LabQuest 3 via Wireless Data Sharing.
  3. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.
Android
Software
InterfaceGraphical AnalysisGraphical Analysis GW
No interface requiredFull supportIncompatible
LabQuest 3Full support 1 2Full support 1
LabQuest 2 (discontinued)Full support 1 2 3Full support 1 3

Compatibility Notes

  1. iOS and Androidâ„¢ devices can only connect to LabQuest 2 or LabQuest 3 via Wireless Data Sharing.
  2. Connect this sensor directly to a supported mobile device via a wireless Bluetooth® connection for best results.
  3. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.
Python
Software
InterfacePython
No interface requiredFull support
Javascript
Software
InterfaceJavascript
No interface requiredFull support 1

Compatibility Notes

  1. A wireless Bluetooth® connection can be made with Go Direct sensors on any platform running a browser with WebBluetooth support. However, only a few operating systems have been tested and testing has been limited.
LabVIEW
Software
InterfaceNI LabVIEW
No interface requiredFull support 1

Compatibility Notes

  1. For Bluetooth® connectivity, only computers running Windows 10 or Mac OS X 10.10 or newer are supported. The computer must also have a compatible Bluetooth 4.0+ radio.

What's Included

  • Go Direct® CO2 Gas Sensor
  • Micro USB Cable
  • 250 mL Nalgene Bottle w/Lid

Accessories

AccessoryOrder CodePriceQuantity
BioChamber 2000BC-2000$22.00
BioChamber 250BC-250$9.00
Go Direct® Charge StationGDX-CRG$89.00
Replacement PartOrder CodePriceQuantity
250 mL Nalgene Bottle w/LidCO2-BTL$5.00
Micro USB CableCB-USB-MICRO$5.00
Go Direct® 650 mAh Replacement BatteryGDX-BAT-650$11.00

Support

Educational use only: Vernier products are designed for educational use. They are not appropriate for industrial, medical, or commercial applications.

SAVE/SHARE YOUR CART