LabQuest Stream joins the LabQuest family to bring wireless and wired connectivity to the mobile learning environment.

Please consider an alternative interface.

ORDER CODE: LQ-STREAM Category
Education Levels
Categories

With LabQuest Stream, our wireless and USB sensor interface, students have the freedom and flexibility to simultaneously collect data from multiple Vernier sensors using a mobile device, a Chromebook, or a computer. Just like the name suggests, students can stream data directly to a mobile device using Bluetooth® connectivity rather than Wi-Fi. That’s especially important for schools where network access may be limited or restricted. In addition, LabQuest Stream includes USB connectivity, which allows it to connect directly to a Chromebook or a computer when needed.

Multi-Platform Compatibility

There are multiple ways to collect data using LabQuest Stream, which is compatible with over 50 Vernier sensors.

Use LabQuest Stream as a wireless interface

  • with our free Graphical Analysis app when students use iOS or Android tablets and phones.
  • with our Logger Pro computer software (version 3.13 or newer)

Use LabQuest Stream with the included USB cable

Key Features

  • Multi-channel sensor interface supports both wireless data collection and USB data collection for multi-platform compatibility. It works in the lab, the classroom, and in the field.
  • Five sensor ports give you the flexibility to choose from over 75 Vernier sensors to support multi-variable experiments and data-logging activities.
  • Collect and analyze sensor data wirelessly with iPad and Android devices
  • This computer interface is compatible with Windows and Mac computers via USB connection. You can also connect wirelessly to computers running Logger Pro.
  • Wireless connectivity using Bluetooth® technology delivers real-time data collection with supported platforms.
  • Connect directly to a Chromebook using a USB cable. Wireless connection to Chromebooks coming in a future update to Graphical Analysis.
  • Real-time wireless data collection—up to 10,000 samples per second
  • Rapid, real-time data collection—up to 100,000 samples per second—when connected via USB
  • High-capacity, rechargeable battery accommodates multiple lab experiments in several classes each day.
  • Charge the battery using an AC adapter or a USB cable.

Awards

ISTE 2016 Best of Show Winner

Tech & Learning recognizes products and services that show the greatest promise according to the country’s most tech-savvy educators. The data-collection interface for science and STEM education was chosen based on its quality, effectiveness, ease of use, and creative use of technology.

Source: Tech & Learning

The Absolute Hub of Discovery

“…let me just say that even though I have used all their interfaces since nineteen-ninety something, this is the most exciting thing since the personal computing power of the device-in-hand was harnessed (which is hugely powerful, by the way, Hugely!.)”

Source: NSTA Recommends

Specifications

Connectivity Bluetooth® or USB
Supports Multiple Sensors Simultaneously Up to 5
Supports Digital Sensors Yes
Maximum Sampling Rate
  • Wireless: 10,000 samples per second
  • USB: 100,000 samples per second
Power Source Rechargeable battery or USB power

What's Included

Accessories

AccessoryOrder CodePriceQuantity
LabQuest 2 Charge StationLQ2-CRG$129.00
Vernier LanyardLQ-LAN$5.00
Mini USB-C CableCB-USB-C-MINI$9.00
LabQuest® Battery Boost 3LQ-BOOST3$119.00
Replacement PartOrder CodePriceQuantity
Mini USB CableCB-USB-MINI$5.00
LabQuest® 2, LabQuest Stream™, and Go Direct SpectroVis Plus BatteryLQ2-BAT$23.00
LabQuest® Power SupplyLQ3-PS$11.00

Software

Windows and Mac

Chromebooks

Other Platforms

LabVIEW: Download LabVIEW VI for collecting data with LabQuest Stream »

Compatible Sensors

Computers and Graphical Analysis (76 sensors)

For All Supported Sensors

  • Connect LabQuest Stream via USB. Wireless connection is not supported.

Supported Sensors

Compatibility Notes

  1. Requires a Motion Detector Cable to connect to a DIG port on the interface
  2. Requires a BNC electrode
  3. Requires a Heart Rate Receiver to connect to an interface
  4. Connect this sensor via Bluetooth® for best results.
  5. The Data Tagging feature typically used with this sensor is not available in the free version of Graphical Analysis; Graphical Analysis Pro activation is required.
  6. Requires an additional signal source, such as LabQuest running the Power Amplifier app or a computer running the Power Amplifier Function Generator Software, to control the Power Amplifier output
  7. Software does not support baseline adjustment.
  8. Use with an electrode such as a pH Sensor, Conductivity Probe, or ORP Sensor.
  9. This interface/software combination can only collect force data; displacement measurements are not supported.
Computers and Logger Pro (81 sensors)

Supported Sensors

Compatibility Notes

  1. Requires a Motion Detector Cable to connect to a DIG port on the interface
  2. Requires a BNC electrode
  3. Requires a Heart Rate Receiver to connect to an interface
  4. Requires an additional signal source, such as LabQuest running the Power Amplifier app or a computer running the Power Amplifier Function Generator Software, to control the Power Amplifier output
  5. Sensor does not auto-ID; manual setup is required.
  6. Requires a Gas Pressure Sensor
  7. Use with an electrode such as a pH Sensor, Conductivity Probe, or ORP Sensor.
Computers and Logger Lite (69 sensors)

For All Supported Sensors

  • Connect LabQuest Stream via USB. Wireless connection is not supported.

Supported Sensors

Compatibility Notes

  1. Requires a Motion Detector Cable to connect to a DIG port on the interface
  2. Requires a BNC electrode
  3. Requires a Heart Rate Receiver to connect to an interface
  4. Requires an additional signal source, such as LabQuest running the Power Amplifier app or a computer running the Power Amplifier Function Generator Software, to control the Power Amplifier output
  5. Requires a Gas Pressure Sensor
  6. Software does not support baseline adjustment.
  7. This interface/software combination auto IDs the VSMT Force sensor; displacement measurements require a Logger Lite file found at www.vernier.com/til/3621/
Chromebook and Graphical Analysis (76 sensors)

For All Supported Sensors

  • Connect LabQuest Stream via USB. Wireless connection is not supported.

Supported Sensors

Compatibility Notes

  1. Requires a Motion Detector Cable to connect to a DIG port on the interface
  2. Requires a BNC electrode
  3. Requires a Heart Rate Receiver to connect to an interface
  4. Connect this sensor via Bluetooth® for best results.
  5. The Data Tagging feature typically used with this sensor is not available in the free version of Graphical Analysis; Graphical Analysis Pro activation is required.
  6. Requires an additional signal source, such as LabQuest running the Power Amplifier app or a computer running the Power Amplifier Function Generator Software, to control the Power Amplifier output
  7. Software does not support baseline adjustment.
  8. Use with an electrode such as a pH Sensor, Conductivity Probe, or ORP Sensor.
  9. This interface/software combination can only collect force data; displacement measurements are not supported.
iOS and Graphical Analysis (76 sensors)

Supported Sensors

Compatibility Notes

  1. Requires a Motion Detector Cable to connect to a DIG port on the interface
  2. Requires a BNC electrode
  3. Connect this sensor via Bluetooth® for best results.
  4. Requires a Heart Rate Receiver to connect to an interface
  5. The Data Tagging feature typically used with this sensor is not available in the free version of Graphical Analysis; Graphical Analysis Pro activation is required.
  6. Requires an additional signal source, such as LabQuest running the Power Amplifier app or a computer running the Power Amplifier Function Generator Software, to control the Power Amplifier output
  7. Software does not support baseline adjustment.
  8. Use with an electrode such as a pH Sensor, Conductivity Probe, or ORP Sensor.
  9. This interface/software combination can only collect force data; displacement measurements are not supported.
iOS and Graphical Analysis GW (63 sensors)

Supported Sensors

Compatibility Notes

  1. Requires a Motion Detector Cable to connect to a DIG port on the interface
  2. Requires a BNC electrode
  3. Data collection will be in mV only. The pH calibration is not supported.
  4. This software cannot apply digital filters to EKG data.
  5. Software does not support the Data Tagging feature that is typically used with this sensor.
  6. Requires an additional signal source, such as LabQuest running the Power Amplifier app or a computer running the Power Amplifier Function Generator Software, to control the Power Amplifier output
  7. Data can be collected using the sensor’s default calibration only.
  8. Use with an electrode such as a pH Sensor, Conductivity Probe, or ORP Sensor.
  9. Requires manual setup of Resistance and Power data using calculated columns.
  10. This interface/software combination can only collect force data; displacement measurements are not supported.
Android and Graphical Analysis (76 sensors)

Supported Sensors

Compatibility Notes

  1. Requires a Motion Detector Cable to connect to a DIG port on the interface
  2. Requires a BNC electrode
  3. Connect this sensor via Bluetooth® for best results.
  4. Requires a Heart Rate Receiver to connect to an interface
  5. The Data Tagging feature typically used with this sensor is not available in the free version of Graphical Analysis; Graphical Analysis Pro activation is required.
  6. Requires an additional signal source, such as LabQuest running the Power Amplifier app or a computer running the Power Amplifier Function Generator Software, to control the Power Amplifier output
  7. Software does not support baseline adjustment.
  8. Use with an electrode such as a pH Sensor, Conductivity Probe, or ORP Sensor.
  9. This interface/software combination can only collect force data; displacement measurements are not supported.
Android and Graphical Analysis GW (50 sensors)

Supported Sensors

Compatibility Notes

  1. Requires a Motion Detector Cable to connect to a DIG port on the interface
  2. Data can be collected using the sensor’s default calibration only.
  3. This software cannot apply digital filters to EKG data.
  4. Requires an additional signal source, such as LabQuest running the Power Amplifier app or a computer running the Power Amplifier Function Generator Software, to control the Power Amplifier output
  5. New Thermocouples (Model: TCA1816R3) are not supported with this software. No Software updates are planned.
  6. Software cannot calculate resistance or power data.
  7. This interface/software combination can only collect force data; displacement measurements are not supported.
NI LabVIEW (77 sensors)

Supported Sensors

Compatibility Notes

  1. Requires a Motion Detector Cable to connect to a DIG port on the interface
  2. Requires advanced programming for data collection
  3. Requires a Heart Rate Receiver to connect to an interface
  4. Requires an additional signal source, such as LabQuest running the Power Amplifier app or a computer running the Power Amplifier Function Generator Software, to control the Power Amplifier output
  5. Sensor does not auto-ID; manual setup is required.

Support

Educational use only: Vernier products are designed for educational use. They are not appropriate for industrial, medical, or commercial applications.

SAVE/SHARE YOUR CART