Experiencing Bluetooth® issues with Go Direct® sensors on Chromebooks? Get help here.

Voltage Probe User Manual

Order Code: VP-BTA

The Voltage Probe is a simple, low-cost solution for voltage measurement in the ±10 V range.

Note: Vernier products are designed for educational use. Our products are not designed nor are they recommended for any industrial, medical, or commercial process such as life support, patient diagnosis, control of a manufacturing process, or industrial testing of any kind.

Compatible Software and Interfaces

Choose a platform below to see its compatibility requirements. This sensor requires an interface (sold separately).

LabQuest
InterfaceLabQuest App
LabQuest 3Full support
LabQuest 2 (discontinued)Full support
LabQuest (discontinued)Full support
Computers
Software
InterfaceGraphical AnalysisLogger ProLogger Lite
LabQuest MiniFull supportFull supportFull support
LabQuest 3Full supportFull supportIncompatible
LabQuest 2 (discontinued)Full supportFull supportFull support
LabQuest Stream (discontinued)Full support 1Full supportFull support 1
Go!LinkFull supportFull supportFull support
LabQuest (discontinued)Full supportFull supportFull support
LabPro (discontinued)IncompatibleFull supportFull support

Compatibility Notes

  1. Connect LabQuest Stream via USB. Wireless connection is not supported.
Chromebook
Software
InterfaceGraphical Analysis
LabQuest MiniFull support
LabQuest 3Full support
LabQuest 2 (discontinued)Full support
LabQuest Stream (discontinued)Full support 1
Go!LinkFull support
LabQuest (discontinued)Full support

Compatibility Notes

  1. Connect LabQuest Stream via USB. Wireless connection is not supported.
iOS
Software
InterfaceGraphical AnalysisGraphical Analysis GW
LabQuest Stream (discontinued)Full supportFull support
LabQuest 3Full support 1Full support 1
LabQuest 2 (discontinued)Full support 1Full support 1

Compatibility Notes

  1. iOS and Androidâ„¢ devices can only connect to LabQuest 2 or LabQuest 3 via Wireless Data Sharing.
Android
Software
InterfaceGraphical AnalysisGraphical Analysis GW
LabQuest Stream (discontinued)Full supportFull support
LabQuest 3Full support 1Full support 1
LabQuest 2 (discontinued)Full support 1Full support 1

Compatibility Notes

  1. iOS and Androidâ„¢ devices can only connect to LabQuest 2 or LabQuest 3 via Wireless Data Sharing.
Arduino
Software
InterfaceArduino
Vernier Arduino® Interface ShieldFull support
LabVIEW
Software
InterfaceNI LabVIEW
SensorDAQ (discontinued)Full support
Go!LinkFull support
LabQuest MiniFull support
LabQuest Stream (discontinued)Full support
LabQuest 3Full support
LabQuest 2 (discontinued)Full support
LabQuest (discontinued)Full support
Texas Instruments
Software
InterfaceEasyDataDataMateTI-84 SmartViewDataQuestTI-Nspire Software
EasyLinkFull support 1IncompatibleFull support 2Full supportFull support 2
CBL 2 (discontinued)Full support 3Full support 3 4IncompatibleIncompatibleIncompatible
LabPro (discontinued)Full support 3Full support 3 4IncompatibleIncompatibleIncompatible
TI-Nspire Lab Cradle (discontinued)IncompatibleIncompatibleIncompatibleFull supportFull support

Compatibility Notes

  1. Use with TI-84 Plus calculators only.
  2. Requires an Easy to Go! adapter
  3. CBL 2 and LabPro interfaces cannot be used with TI-84 Plus CE calculators.
  4. DataMate cannot be used with color screen TI-84 Plus calculators; use EasyData with these calculators.

Quick Start

  1. Plug the sensor into the interface (LabQuest 3, LabQuest Mini, etc.).
  2. Connect the interface to your device.
    • If using USB, connect to the USB port on your computer.
    • If using Bluetooth® wireless technology, click your interface type and then select your device.
  3. Prepare for data collection:
    • Vernier Graphical Analysis®: Launch the app, if necessary, and click Sensor Data Collection.
    • LabQuest® App: Choose New from the File menu.

The software will identify the sensor and load a default data-collection setup. You are now ready to collect data.

Need Additional Information?

Visit the following link:

www.vernier.com/start-lq-sensor

Using the Product

Connect the sensor following the steps in the Quick Start section of this user manual.

To measure a potential difference between two points in a circuit, connect the red and black clips to the two points. A positive reading means the red clip is at a higher potential than the black clip.

Calibration

The Voltage Probe does not require calibration. Zeroing can be helpful in improving the accuracy of measurements. Zero the Voltage Probe before a measurement by connecting the two leads together and zeroing the reading in the software.

How the Sensor Works

The Voltage Probe is a direct connection to the inputs of the particular interface. As a result, it is not a true differential voltage sensor and should not be expected to behave like a traditional voltmeter.

  • The black lead is directly connected to the common ground point of the interface. In some circumstances, this means the black lead is grounded. Because of this connection to the common ground point of the interface, it is easy to unintentionally ground part of your circuit without realizing it. Connect the black lead only to a point in your circuit that can safely be grounded.
  • Because of the common black connection, when two or more voltage probes are used, the black leads must be connected to a common point in the circuit or unexpected short circuits will be introduced.
  • The voltage probe may give unexpected non-zero readings when disconnected or open-circuited. This is normal and is due to the technical details of the particular interface used.

Troubleshooting

If you are getting unexpected or unusual measurements from your Voltage Probe, first check that the red and black leads are properly and securely attached, according to the experimental setup. If you suspect that the readings are not correct, make sure you have zeroed the probe correctly. To do this, connect the red and black clips together. Zero the probe in the software. The reading should go to zero. If it does not, the wires may be damaged.

For additional troubleshooting tips and FAQs, see www.vernier.com/til/1425

Repair Information

If you have followed the troubleshooting steps and are still having trouble with your Voltage Probe, contact Vernier Technical Support at support@vernier.com or call 888-837-6437. Support specialists will work with you to determine if the unit needs to be sent in for repair. At that time, a Return Merchandise Authorization (RMA) number will be issued and instructions will be communicated on how to return the unit for repair.

Warranty

Warranty information for this product can be found on the Support tab at www.vernier.com/vp-bta/#support

General warranty information can be found at www.vernier.com/warranty

Contact Support

Fill out our online support form or call us toll-free at 1-888-837-6437.

SAVE/SHARE YOUR CART