Supported Software
Platform | Version |
---|---|
Android OS | ● Graphical Analysis for Android (v2.2 – 3.1) ● Graphical Analysis GW for Android |
iOS & iPadOS | ● Graphical Analysis for iOS (v2.3 – 4.0.3) ● Graphical Analysis GW for iOS |
LabQuest App | ● LabQuest 3 – All versions ● LabQuest 2 – v2.6 or higher ● Original LabQuest – Unsupported |
Supported Sensors
- 30-Volt Voltage Probe (30V-BTA)
- 3-Axis Accelerometer (3D-BTA)
⚬ only one axis at a time (not two or three simultaneously) - 25-g Accelerometer (ACC-BTA)
- Anemometer (ANM-BTA)
- Barometer (BAR-BTA)
- Calcium Ion-Selective Electrode (CA-BTA)
⚬ Not supported on Android (unsupported calibration) - Constant Current System (CCS-BTA)
- Chloride Ion-Selective Electrode (CL-BTA)
⚬ Not supported on Android (unsupported calibration) - CO2 Gas Sensor (CO2-BTA)
- Colorimeter (COL-BTA)
- Conductivity Probe (CON-BTA)
⚬ Default calibration only on Android - Platinum-Cell Conductivity Probe (CONPT-BTA)
⚬ Default calibration only on Android - Charge Sensor (CRG-BTA)
- Current Probe (DCP-BTA)
- Dual-Range Force Sensor (DFS-BTA)
⚬ Maximum data rate may limit the sensor’s response in collision experiments. - Dissolved Oxygen Probe (DO-BTA)
⚬ Default calibration only on Android - Differential Voltage Probe (DVP-BTA)
- Vernier Optical DO Probe (ODO-BTA)
- Electrode Amplifier (EA-BTA)
⚬ data collection in mV only; pH calibration is not supported
⚬ Not supported on Android (unsupported calibration) - Flow Rate Sensor (FLO-BTA)
- Force Plate (FP-BTA)
- Goniometer (GNM-BTA)
⚬ Default calibration only on Android - Gas Pressure Sensor (GPS-BTA)
- High Current Sensor (HCS-BTA)
- Hand Dynamometer (HD-BTA)
- Instrumentation Amplifier (INA-BTA)
- Infrared Thermometer (IRT-BTA, discontinued)
- Potassium Ion-Selective Electrode (K-BTA)
⚬ Not supported on Android (unsupported calibration) - Low-g Accelerometer (LGA-BTA)
- Light Sensor (LS-BTA)
- Magnetic Field Sensor (MG-BTA)
- Melt Station (MLT-BTA)
⚬ Not supported on Android (unsupported calibration) - Ammonium Ion-Selective Electrode (NH4-BTA)
⚬ Not supported on Android (unsupported calibration) - Nitrate Ion-Selective Electrode (NO3-BTA)
⚬ Not supported on Android (unsupported calibration) - O2 Gas Sensor (O2-BTA)
⚬ Default calibration only on Android - Vernier Optical DO Probe (ODO-BTA)
- ORP Sensor (ORP-BTA)
⚬ Default calibration only on Android - Power Amplifier (PAMP)
⚬ for monitoring the internal current of the Power Amplifier only - PAR Sensor (PAR-BTA)
- pH Sensor (PH-BTA)
⚬ Default calibration only on Android - Pressure Sensor 400 (PS400-BTA)
- Pyranometer (PYR-BTA)
- Relative Humidity Sensor (RH-BTA)
- Salinity Sensor (SAL-BTA)
⚬ Default calibration only on Android - Sound Level Meter (SLM-BTA, discontinued)
- Sound Level Sensor (SLS-BTA)
⚬ Not supported on Android (unsupported calibration) - Soil Moisture Sensor (SMS-BTA)
- Surface Temperature Sensor (STS-BTA)
- Thermocouple (TCA-BTA)
⚬ Model TCA1816R3: not supported on Android (unsupported calibration)
⚬ Older model: default calibration only on Android - Extra-Long Temperature Probe (TPL-BTA)
- TI Light Probe (TILT-BTA, discontinued)
- Stainless Steel Temperature Probe (TMP-BTA)
- Turbidity Sensor (TRB-BTA)
⚬ Default calibration only on Android - UVA Sensor (UVA-BTA)
- UVB Sensor (UVB-BTA)
- Vernier Energy Sensor (VES-BTA)
⚬ Either Current sensor or Voltage sensor (not both simultaneously) - Voltage Probe (VP-BTA)
- Vernier Structures & Materials Tester (VSMT)
⚬ Force sensor only, linear displacement sensor is not supported - Wide-Range Temperature Probe (WRT-BTA)
⚬ Not supported on Android (unsupported calibration)