The Melt Station makes it possible to accurately determine the melting temperature of solid substances.

ORDER CODE: MLT-BTA Categories ,

Connect the Melt Station to a Vernier interface to measure the melting temperature of solid substances.

  • Accurate results using built-in RTD over a range of 30°C to 260°C
  • High-quality 6X viewing lens for clear observation of the samples
  • Innovative, adjustable tilt allows for optimal viewing angle
  • Cooling fan reduces time between tests

Each Melt Station comes with 100 standard capillary tubes. Additional packages of 100 are available.

WARNING: This product can expose you to chemicals, including nickel, which are known to the State of California to cause cancer. For more information, see www.P65Warnings.ca.gov

Specifications

  • Dimensions:
    • Base: 13 cm x 15 cm x 1.5 cm
    • Body: 9 cm x 9 cm x 24 cm
  • Weight: 1.0 kg (2.2 lbs)
  • Resolution: 0.10°C
  • Accuracy: ± 0.31 + 0.0006T, where T is the temperature in Celsius
  • Safety shut down: The heating block is automatically powered down after approximately sixty minutes of heating.
  • Capillary tubes: 1.4–1.8 mm outside diameter, 100 mm length
  • Capillary tube slots: 3
  • Viewing Lens: 27 mm diameter (functional), 30 mm (actual)
  • Lighting of capillary slots: 3 white LEDs
  • Lighting of Control Dial:
    • Red LED (indicates heating mode)
    • Blue LED (indicates cooling mode with cooling fan running)
    • Yellow LED (safety shut off activated)

Experiments

High School (3 experiments)
College (9 experiments)

Requirements

Choose a platform below to see its compatibility requirements. This sensor requires an interface (sold separately).

LabQuest
InterfaceLabQuest App
LabQuest 3Full support
LabQuest 2 (discontinued)Full support
LabQuest (discontinued)Full support
Computers
Software
InterfaceGraphical AnalysisLogger ProLogger Lite
LabQuest MiniFull support 1Full supportFull support
LabQuest 3Full support 1 2Full supportIncompatible
LabQuest 2 (discontinued)Full support 1 2Full supportFull support
LabQuest Stream (discontinued)Full support 1 3Full supportFull support 3
Go!LinkFull support 1Full supportFull support
LabQuest (discontinued)Full support 1Full supportFull support
LabPro (discontinued)IncompatibleFull supportFull support

Compatibility Notes

  1. The Data Tagging feature typically used with this sensor is not available in the free version of Graphical Analysis; Graphical Analysis Pro activation is required.
  2. Full support of this sensor is only available when LabQuest 2 or LabQuest 3 is connected to a computer or Chromebook via Wireless Data Sharing.
  3. Connect LabQuest Stream via USB. Wireless connection is not supported.
Chromebook
Software
InterfaceGraphical Analysis
LabQuest MiniFull support 1
LabQuest 3Full support 1 2
LabQuest 2 (discontinued)Full support 1 2
LabQuest Stream (discontinued)Full support 1 3
Go!LinkFull support 1
LabQuest (discontinued)Full support 1

Compatibility Notes

  1. The Data Tagging feature typically used with this sensor is not available in the free version of Graphical Analysis; Graphical Analysis Pro activation is required.
  2. Full support of this sensor is only available when LabQuest 2 or LabQuest 3 is connected to a computer or Chromebook via Wireless Data Sharing.
  3. Connect LabQuest Stream via USB. Wireless connection is not supported.
iOS
Software
InterfaceGraphical AnalysisGraphical Analysis GW
LabQuest Stream (discontinued)Full support 1Full support 2
LabQuest 3Full support 3Full support 3
LabQuest 2 (discontinued)Full support 3Full support 3

Compatibility Notes

  1. The Data Tagging feature typically used with this sensor is not available in the free version of Graphical Analysis; Graphical Analysis Pro activation is required.
  2. Software does not support the Data Tagging feature that is typically used with this sensor.
  3. iOS and Androidâ„¢ devices can only connect to LabQuest 2 or LabQuest 3 via Wireless Data Sharing.
Android
Software
InterfaceGraphical AnalysisGraphical Analysis GW
LabQuest Stream (discontinued)Full support 1Incompatible
LabQuest 3Full support 2Full support 2
LabQuest 2 (discontinued)Full support 2Full support 2

Compatibility Notes

  1. The Data Tagging feature typically used with this sensor is not available in the free version of Graphical Analysis; Graphical Analysis Pro activation is required.
  2. iOS and Androidâ„¢ devices can only connect to LabQuest 2 or LabQuest 3 via Wireless Data Sharing.
Arduino
Software
InterfaceArduino
Vernier Arduino® Interface ShieldFull support 1

Compatibility Notes

  1. Requires advanced programming for data collection
LabVIEW
Software
InterfaceNI LabVIEW
SensorDAQ (discontinued)Full support
Vernier myDAQ AdapterFull support 1 2
Go!LinkFull support 2
LabQuest MiniFull support
LabQuest Stream (discontinued)Full support
LabQuest 3Full support
LabQuest 2 (discontinued)Full support
LabQuest (discontinued)Full support

Compatibility Notes

  1. You can only read the raw count/raw voltage output by this sensor. You must do the programming to convert to proper sensor units.
  2. Requires advanced programming for data collection
Texas Instruments
Software
InterfaceEasyDataTI-84 SmartViewDataQuestTI-Nspire Software
EasyLinkFull support 1 2Full support 2 3Full supportFull support 3
CBL 2 (discontinued)Full support 2 4IncompatibleIncompatibleIncompatible
LabPro (discontinued)Full support 2 4IncompatibleIncompatibleIncompatible
TI-Nspire Lab Cradle (discontinued)IncompatibleIncompatibleFull supportFull support

Compatibility Notes

  1. Use with TI-84 Plus calculators only.
  2. Software does not support the Data Tagging feature that is typically used with this sensor.
  3. Requires an Easy to Go! adapter
  4. CBL 2 and LabPro interfaces cannot be used with TI-84 Plus CE calculators.

What's Included

Accessories

AccessoryOrder CodePriceQuantity
Melt Station Capillary TubesMLT-TUBE$24.00
Replacement PartOrder CodePriceQuantity
Replacement Melt Station Power SupplyMLT-PS$20.00

Support

Warranty

5-year limited warranty (consumables excluded)
See our warranty policy

Replacement Parts

Contact Us

Educational use only: Vernier products are designed for educational use. They are not appropriate for industrial, medical, or commercial applications.

SAVE/SHARE YOUR CART