Extra-Long Temperature Probe User Manual
Order Code: TPL-BTA
This probe is designed for outdoor temperature sensing or for measuring temperature at various depths in lakes and rivers. It has a 30 m (100 ft) cable that can be submersed in water up to the cable box.
Note: Vernier products are designed for educational use. Our products are not designed nor are they recommended for any industrial, medical, or commercial process such as life support, patient diagnosis, control of a manufacturing process, or industrial testing of any kind.
Compatible Software and Interfaces
Choose a platform below to see its compatibility requirements. This sensor requires an interface (sold separately).LabQuest
Interface LabQuest App LabQuest 3 Full support LabQuest 2 (discontinued) Full support LabQuest (discontinued) Full support Computers
Software Interface Graphical Analysis Logger Pro Logger Lite LabQuest Mini Full support Full support Full support LabQuest 3 Full support Full support Incompatible LabQuest 2 (discontinued) Full support Full support Full support LabQuest Stream (discontinued) Full support 1 Full support Full support 1 Go!Link Full support Full support Full support LabQuest (discontinued) Full support Full support Full support LabPro (discontinued) Incompatible Full support Full support Compatibility Notes
Chromebook
Software Interface Graphical Analysis LabQuest Mini Full support LabQuest 3 Full support LabQuest 2 (discontinued) Full support LabQuest Stream (discontinued) Full support 1 Go!Link Full support LabQuest (discontinued) Full support Compatibility Notes
iOS
Software Interface Graphical Analysis Graphical Analysis GW LabQuest Stream (discontinued) Full support Full support LabQuest 3 Full support 1 Full support 1 LabQuest 2 (discontinued) Full support 1 Full support 1 Compatibility Notes
Android
Software Interface Graphical Analysis Graphical Analysis GW LabQuest Stream (discontinued) Full support Full support LabQuest 3 Full support 1 Full support 1 LabQuest 2 (discontinued) Full support 1 Full support 1 Compatibility Notes
Arduino
Software Interface Arduino Vernier Arduino® Interface Shield Full support LabVIEW
Software Interface NI LabVIEW SensorDAQ (discontinued) Full support Vernier myDAQ Adapter Full support 1 Go!Link Full support LabQuest Mini Full support LabQuest Stream (discontinued) Full support LabQuest 3 Full support LabQuest 2 (discontinued) Full support LabQuest (discontinued) Full support Compatibility Notes
Texas Instruments
Software Interface EasyData DataMate TI-84 SmartView DataQuest TI-Nspire Software EasyLink Full support 1 Incompatible Full support 2 Full support Full support 2 CBL 2 (discontinued) Full support 3 Full support 3 4 Incompatible Incompatible Incompatible LabPro (discontinued) Full support 3 Full support 3 4 Incompatible Incompatible Incompatible TI-Nspire Lab Cradle (discontinued) Incompatible Incompatible Incompatible Full support Full support Compatibility Notes
Getting Started
- Connect the sensor to the interface (LabQuest Mini, LabQuest 3, etc.).
- Start the appropriate data-collection software (Vernier Graphical Analysis®, LabQuest® App, or Logger Proâ„¢) if not already running, and choose New from File menu. The software will identify the sensor and load a default data‑collection setup. You are now ready to collect data.
If you are collecting data using a Chromebook™, mobile device such as iPad® or Android™ tablet, or a Vernier wireless interface, please see the following link for up-to-date connection information:
Using the Product
Connect the sensor following the steps in the Getting Started section of this user manual.
Videos
Calibration
You should not have to perform a new calibration when using the Extra‑Long Temperature Probe. The sensor is custom calibrated before it is shipped. However, a two-point calibration can be performed and saved on the sensor, if desired.
Specifications
Range |
–50 to 150˚C |
Maximum temperature the sensor can tolerate without damage |
200ËšC |
Accuracy |
±1.0°C at 25˚C |
12-bit resolution |
0.07°C |
Response time (in moving water from 25 to 50ËšC) |
60 seconds |
Stored calibration values (Celsius) |
|
Stored calibration values (Fahrenheit) |
|
How the Sensor Works
The Extra-Long Temperature Probe uses a transducer to produce a current that is directly proportional to its absolute temperature. The sensor is plugged into a signal conditioning box, producing an output voltage that is linear with temperature over the range of –50 to +150°C.
The transducer is at the tip of the brass tube. The entire probe is covered with Teflon® FEP heat-shrink tubing. This coating protects the probe from damage in most environments.
For use in anything other than air or water, see www.vernier.com/til/3742
The Extra-Long Temperature Probe is designed so that it can be submerged in a water environment for extended periods of time. If the Teflon coating is damaged, however, liquid may get into the probe and cause errant readings.
Repair Information
If you have watched the related product video(s), followed the troubleshooting steps, and are still having trouble with your Extra-Long Temperature Probe, contact Vernier Technical Support at support@vernier.com or call 888-837-6437. Support specialists will work with you to determine if the unit needs to be sent in for repair. At that time, a Return Merchandise Authorization (RMA) number will be issued and instructions will be communicated on how to return the unit for repair.
Warranty
Warranty information for this product can be found on the Support tab at www.vernier.com/tpl-bta/#support
General warranty information can be found at www.vernier.com/warranty
Contact Support
Fill out our online support form or call us toll-free at 1-888-837-6437.