Anemometer User Manual

Order Code: ANM-BTA

The Vernier Anemometer is a device for measuring wind speed. You can also

  • Measure the wind speed of air generated by a variable speed fan.
  • Use the anemometer and a Vernier Energy Sensor to investigate the effect of design, number, and size of rotors and blades of a windmill's electrical energy output.
  • Use the anemometer and a Vernier Infrared Thermometer to determine how wind speed affects the rate of cooling of an object.
  • Investigate why wind speed is slower over land than it is over the ocean.
  • Use an anemometer and a compass to determine wind direction.

Note: Vernier products are designed for educational use. Our products are not designed nor recommended for any industrial, medical, or commercial process such as life support, patient diagnosis, control of a manufacturing process, or industrial testing of any kind.

Compatible Software and Interfaces

Choose a platform below to see its compatibility requirements. This sensor requires an interface (sold separately).

LabQuest
InterfaceLabQuest App
LabQuest 3Full support
LabQuest 2 (discontinued)Full support
LabQuest (discontinued)Full support
Computers
Software
InterfaceGraphical AnalysisLogger ProLogger Lite
LabQuest MiniFull supportFull supportFull support
LabQuest 3Full supportFull supportIncompatible
LabQuest 2 (discontinued)Full supportFull supportFull support
LabQuest Stream (discontinued)Full support 1Full supportFull support 1
Go!LinkFull supportFull supportFull support
LabQuest (discontinued)Full supportFull supportFull support
LabPro (discontinued)IncompatibleFull supportFull support

Compatibility Notes

  1. Connect LabQuest Stream via USB. Wireless connection is not supported.
Chromebook
Software
InterfaceGraphical Analysis
LabQuest MiniFull support
LabQuest 3Full support
LabQuest 2 (discontinued)Full support
LabQuest Stream (discontinued)Full support 1
Go!LinkFull support
LabQuest (discontinued)Full support

Compatibility Notes

  1. Connect LabQuest Stream via USB. Wireless connection is not supported.
iOS
Software
InterfaceGraphical AnalysisGraphical Analysis GW
LabQuest Stream (discontinued)Full supportFull support
LabQuest 3Full support 1Full support 1
LabQuest 2 (discontinued)Full support 1Full support 1

Compatibility Notes

  1. iOS and Androidâ„¢ devices can only connect to LabQuest 2 or LabQuest 3 via Wireless Data Sharing.
Android
Software
InterfaceGraphical AnalysisGraphical Analysis GW
LabQuest Stream (discontinued)Full supportFull support
LabQuest 3Full support 1Full support 1
LabQuest 2 (discontinued)Full support 1Full support 1

Compatibility Notes

  1. iOS and Androidâ„¢ devices can only connect to LabQuest 2 or LabQuest 3 via Wireless Data Sharing.
Arduino
Software
InterfaceArduino
Vernier Arduino® Interface ShieldFull support
LabVIEW
Software
InterfaceNI LabVIEW
SensorDAQ (discontinued)Full support
Vernier myDAQ AdapterFull support 1
Go!LinkFull support
LabQuest MiniFull support
LabQuest Stream (discontinued)Full support
LabQuest 3Full support
LabQuest 2 (discontinued)Full support
LabQuest (discontinued)Full support

Compatibility Notes

  1. You can only read the raw count/raw voltage output by this sensor. You must do the programming to convert to proper sensor units.
Texas Instruments
Software
InterfaceEasyDataDataMateTI-84 SmartViewDataQuestTI-Nspire Software
EasyLinkFull support 1IncompatibleFull support 2Full supportFull support 2
CBL 2 (discontinued)Full support 3Full support 3 4IncompatibleIncompatibleIncompatible
LabPro (discontinued)Full support 3Full support 3 4IncompatibleIncompatibleIncompatible
TI-Nspire Lab Cradle (discontinued)IncompatibleIncompatibleIncompatibleFull supportFull support

Compatibility Notes

  1. Use with TI-84 Plus calculators only.
  2. Requires an Easy to Go! adapter
  3. CBL 2 and LabPro interfaces cannot be used with TI-84 Plus CE calculators.
  4. DataMate cannot be used with color screen TI-84 Plus calculators; use EasyData with these calculators.

Getting Started

  1. Plug the sensor into the interface (LabQuest 3, LabQuest Mini, etc.).
  2. Connect the interface to your device.
    • If using USB, connect to the USB port on your computer.
    • If using Bluetooth® wireless technology, click your interface type and then select your device.
  3. Prepare for data collection:
    • Vernier Graphical Analysis®: Launch the app, if necessary, and click Sensor Data Collection.
    • LabQuest® App: Choose New from the File menu.

The software will identify the sensor and load a default data-collection setup. You are now ready to collect data.

Need Additional Information?

Visit the following link:

www.vernier.com/start-lq-sensor

Using the Sensor

To use the anemometer, hold it so that the wind blows directly into the anemometer. This will cause the impeller to spin. The anemometer also has a standard 1/4 – 20 mount that will connect to any standard camera mount on a tripod.

Calibration

You should not have to perform a new calibration when using the anemometer. We have set the sensor to match our stored calibration before shipping it. You can simply use the appropriate calibration value that is stored in the data-collection program.

Specifications

Operational range

0.5–30 m/s

Power

7 mA @ 5VDC

Operating temperature

0ËšC to 50ËšC

Storage temperature

–20˚C to 60˚C

How the Sensor Works

The Vernier Anemometer is an impeller-type anemometer with the axis of rotation parallel to the direction of the wind. It uses a magnet located in the impeller and an inductor. Wind causes rotation of the impeller, magnet, and shaft. The rotation of the magnet produces an electrical signal proportional to the wind speed.

Troubleshooting

Troubleshooting information is available at www.vernier.com/til/2320

Repair Information

If you have followed the troubleshooting steps and are still having trouble with your Anemometer, contact Vernier Technical Support at support@vernier.com or call 888-837-6437. Support specialists will work with you to determine if the unit needs to be sent in for repair. At that time, a Return Merchandise Authorization (RMA) number will be issued and instructions will be communicated on how to return the unit for repair.

Warranty

Warranty information for this product can be found on the Support tab at www.vernier.com/anm-bta/#support

General warranty information can be found at www.vernier.com/warranty

Contact Support

Fill out our online support form or call us toll-free at 1-888-837-6437.

SAVE/SHARE YOUR CART