CBL 2

CBL 2

The CBL 2 is a multi-channel sensor interface for older Texas Instruments graphing calculators such as the TI-83 Plus and TI-84 Plus (made before 2023).

Looking for a sensor interface for newer Texas Instruments calculators? See our EasyLink.

ORDER CODE: CBL2 Category

For classrooms with older, compatible TI graphing calculators, the CBL 2 is an inexpensive way to collect sensor data.

The CBL 2 is portable and battery powered, you can take it out of the classroom for experiments such as measuring accelerations on amusement rides or monitoring the temperature, dissolved oxygen, and pH of a lake or stream.

Specifications

  • Resolution: 10-bit A/D conversion
  • Maximum sampling rate: 50,000 readings per second
  • Sensor channels: 3 analog and 1 digital
  • Internal memory: Stores up to 12,000 data points

Compatible TI Graphing Calculators

  • TI-73 Explorer
  • TI-82
  • TI-83
  • TI-83 Plus
  • TI-84 Plus (made prior to 2023)
  • TI-84 Plus Silver Edition
  • TI-84 Plus C Silver Edition
  • TI-86
  • TI-89
  • TI-89 Titanium
  • TI-92
  • TI-92 Plus
  • TI Voyage

CBL 2 is not compatible with TI-Nspire calculators, TI-84 Plus CE, or TI-84 Plus calculators made after 2022.

What's Included

  • CBL 2 interface
  • Stainless steel temperature probe
  • Light probe
  • Voltage probe
  • Calculator cradle and link cable
  • User’s guide

Accessories

AccessoryOrder CodePriceQuantity
Power Supply for LabPro, WDSS, and Stir StationIPS$12.00
Replacement PartOrder CodePriceQuantity
Calculator Link CableTI-CLC$5.00
Short Calculator Link CableTI-SLC$5.00

Compatible Sensors

TI Calculators and EasyData (75 sensors)

For All Supported Sensors

  • CBL 2 and LabPro interfaces cannot be used with TI-84 Plus CE calculators.

Supported Sensors

Compatibility Notes

  1. Requires a Motion Detector Cable to connect to a DIG port on the interface
  2. Requires user-defined programs
  3. Requires a BNC electrode
  4. This software cannot apply digital filters to EKG data.
  5. Requires a Heart Rate Receiver to connect to an interface
  6. Software does not support the Data Tagging feature that is typically used with this sensor.
  7. Requires an additional signal source, such as LabQuest running the Power Amplifier app or a computer running the Power Amplifier Function Generator Software, to control the Power Amplifier output
  8. Requires a Gas Pressure Sensor
  9. EasyData and DataMate do not support this sensor. Use DaRotary (not supported on color screen TI-84 Plus calculators).
  10. Software does not support baseline adjustment.
  11. Use with an electrode such as a pH Sensor, Conductivity Probe, or ORP Sensor.
  12. Software cannot calculate resistance or power data.
  13. EasyData and DataMate do not support this sensor. Use DataRad (not supported on color screen TI-84 Plus calculators).
  14. This interface/software combination can only collect force data; displacement measurements are not supported.
TI Calculators and DataMate (71 sensors)

For All Supported Sensors

  • DataMate cannot be used with color screen TI-84 Plus calculators; use EasyData with these calculators.
  • CBL 2 and LabPro interfaces cannot be used with TI-84 Plus CE calculators.

Supported Sensors

Compatibility Notes

  1. Requires a Motion Detector Cable to connect to a DIG port on the interface
  2. Requires user-defined programs
  3. Requires a BNC electrode
  4. This software cannot apply digital filters to EKG data.
  5. Requires a Heart Rate Receiver to connect to an interface
  6. Requires an additional signal source, such as LabQuest running the Power Amplifier app or a computer running the Power Amplifier Function Generator Software, to control the Power Amplifier output
  7. Requires a Gas Pressure Sensor
  8. EasyData and DataMate do not support this sensor. Use DaRotary (not supported on color screen TI-84 Plus calculators).
  9. Software does not support baseline adjustment.
  10. Currently shipping Thermocouples (Model: TCA1816R3) use a calibration type not supported with this software. Older models of the sensor are fully supported. No software update is planned.
  11. DataMate does not support this sensor. Use EasyData app with all TI-83/84 Plus calculators; otherwise, use DataGate.
  12. DataMate does not support this sensor. Use EasyData app with all TI-83/84 Plus calculators; otherwise, use DataDrop.
  13. Use with an electrode such as a pH Sensor, Conductivity Probe, or ORP Sensor.
  14. Software cannot calculate resistance or power data.
  15. EasyData and DataMate do not support this sensor. Use DataRad (not supported on color screen TI-84 Plus calculators).
  16. This interface/software combination can only collect force data; displacement measurements are not supported.